Validation Results

5aa7fdbc08458a0004000014

https://www.cardiovibe.de/backend/export/index/idealo.csv?feedID=4&hash=2648057f0020fbeb7e69c238036b25e8

Sorry, your CSV did not pass validation. Please review the errors and warnings below:

Total Rows Processed = 131

Download Standardised CSV
132Errors 3Warnings 0Messages
Structure 131 0 0
Schema 0 0 0
Context 1 2 0

132 Errors, 3 Warnings

Context problem: Incorrect content type

Your CSV file is being delivered with an incorrect Content-Type of text/x-comma-separated-values;charset=iso-8859-1.
We recommend that you configure your server to deliver CSV files with a Content-Type header of text/csv; charset=utf-8

Structural problem: Stray quote on row 2

"EMS Ger�te>Globus Italia";Globus Italia;"Globus Runner Pro - EMS f�r L�ufer";399,00;G4229;"8032625826811";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/ems-fuer-laeufer-runner-pro/;2-3 Tage;"4229";https://www.cardiovibe.de/media/image/1d/e3/c1/runner-pro-ems-fuer-laeufer_1280x1280.jpg;"Der RUNNER Pro von Globus Italia ist ein neues EMS Ger�t, dass speziell f�r die Anforderungen von L�ufern und Gehern entwickelt wurde. Durch das EMS Training erfolgt eine optimale Erg�nzung des klassischen Lauftrainings. Daher ist der Runner Pro perfekt f�r alle L�ufer geeignet, die eine Steigeru..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 3

"EMS Ger�te>Globus Italia";Globus Italia;"Globus Cycling Pro - EMS f�r Radsportler";399,00;G4230;"8032625826828";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/ems-training-radsport-cycling-pro/;2-3 Tage;"4187";https://www.cardiovibe.de/media/image/94/3e/0a/cycling-pro-radsport-ems_1280x1280.jpg;"EMS Training f�r Radsportler | Cycling Pro Muskelstimulator Das Cycling Pro Muskelstimulationsger�t ist speziell f�r Radsportler entwickelt worden, die eine Unterst�tzung des regul�ren Radtrainings durch die EMS (elektrische Muskelstimulation) erreichen wollen.Das EMS Training ist f�r viele Radpr..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 4

"Magnetfeldtherapie>Magnetfeldtherapie Ger�te";Globus Italia;"Globus Magnum L - Magnetfeldger�t";290,00;G3947;"8032625826194";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/magnetfeldtherapie-geraet-globus-magnum-l;2-3 Tage;"3947";https://www.cardiovibe.de/media/image/dc/06/57/magnetfeldtherapie-magnum-l_1280x1280.jpg;"Das Einsteiger Magnetfeld-Ger�t Magnum L von Globus Italia ist wie die gr��eren Br�der ebenfalls mit Niedrigfrequenz - Magnetfeldern ausgestattet. Insgesamt stehen 8 Programme aus den Bereichen Schmerz und Rehabilitation zur Verf�gung. Das Ger�t arbeitet in der Spitze im Bereich 160 Gauss, im Sch..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 5

"Hochfrequenzger�te>Radiofrequenzger�te";Globus Italia;"Globus RF Clinic Body";799,00;G1507;"8032625825708";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/hochfrequenztherapie-globus-clinic-body;2-3 Tage;"1507";https://www.cardiovibe.de/media/image/1c/38/74/rf-clinic-body_1280x1280.jpg;"Globus Italia hat mit dem RF Clinic Body ein innovatives und professionelles Radiofrequenz Ger�t entwickelt, dass f�r �sthetische Anwendungen bestens geeignet ist. F�r alle Anwender, die die Hochfrequenztechnik f�r Antiaging Anwendungen im Gesicht und am K�rper nutzen wollen. Dabei kann das RF Cl..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 6

"EMS Ger�te>Globus Italia";Globus Italia;"Globus Genesy SII TENS / EMS Ger�t";229,00;G3725;"8032625826026";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/genesy-s2-tens-ems-geraet/;2-3 Tage;"3726";https://www.cardiovibe.de/media/image/d5/9f/6e/genesy-s2-reha-ems_1280x1280.jpg;"Hochwertiges TENS / EMS Ger�t f�r Beauty-, Reha-, Schmerz- und Inkontinenz Anwendungen Globus hat mit dem Genesy�SII einen hochwertigen 2-Kanal Muskelstimulator entwickelt, der sowohl f�r professionelle Anwender wie Physiotherapeuten, als auch Privatanwender gedacht ist. Der Genesy�SII ..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 7

"EMS Ger�te>Globus Italia";Globus Italia;"Globus Soccer Pro - EMS f�r Fu�ball";399,00;G4258;"8032625826798";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/soccer-pro-ems-geraet-fussball/;2-3 Tage;"3672";https://www.cardiovibe.de/media/image/4d/f9/bf/soccer-pro-fussball-training_1280x1280.jpg;"EMS Training Fu�ball - optimale Trainingserg�nzung f�r Fu�baller Globus Italia erweitert mit dem Soccer Pro seine Ger�telinie f�r Spezialsportarten. Der Soccer Pro ist ein speziell f�r Fu�baller entwickeltes EMS Ger�t , mit vielen EMS Spezialprogrammen, die f�r einen Fu�ballspieler Sinn machen.&n..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 8

"Hochfrequenzger�te>Diathermieger�te";Globus Italia;"Globus DiaCare 1000 - Diathermie";4850,00;G3177;"8032625825777";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/globus-diathermie-diacare-1000;2-3 Tage;"3117";https://www.cardiovibe.de/media/image/21/c7/60/diacare-1000_1280x1280.jpg;"Mit dem Diacare 1000 bietet Globus Italia einen attraktiven Einstieg in die Diathermie, sowohl f�r den professionellen Bereich, als auch f�r anspruchsvolle Privatanwender. Die Diathermie (oder auch Tecartherapie) als revolution�re neue Technik, wird von Physiotherapie Praxen und Rehakliniken imme..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 9

"EMS Ger�te>Zubeh�r Globus";Globus Italia;"8 leitende, elastische B�nder f�r Oberschenkel und Waden";85,90;;"";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/elastische-baender-ems-oberschenkeltraining;"3" Tage;"0479";https://www.cardiovibe.de/media/image/da/c1/86/elastische-leitende-baender_1280x1280.jpg;"Ein Set aus 8 elastischen, leitenden B�ndern in 3 unterschiedlichen Gr��en enthalten (2 B�nder 5x65 cm + 2 B�nder 5x50 cm f�r die Oberschenkel ? 4 B�nder 5x40 cm f�r die Waden). Man legt die B�nder um jeweils den oberen und unteren Teil des Oberschenkels und genau so an den Waden. Dann wird das g..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 10

"Ballwurfmaschinen>Volleyball>Volleyball Ballmaschinen";Globus Italia;"Globus Winshot 1500 Volleyball-Wurfmaschine";6435,00;;"";;;0,00;120,00;0,00;0,00;https://www.cardiovibe.de/winshot-1500-volleyballmaschine;2-3 Tage;"7411";https://www.cardiovibe.de/media/image/5e/85/bc/winshot-1500-ballwurfmaschine_1280x1280.jpg;"Die Winshot 1500 ist eine State-of-The-Art Volleyball Trainingsmaschine. Mit dieser Ballwurfmaschine k�nnen sehr realistisch die Annahme von Aufschl�gen in allen Variationen, Zuspielen und die Annahme von Angriffschl�gen von der ersten oder zweiten Linie trainiert werden. Dabei kann die Winshot 1..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 11

"EMS Ger�te>Zubeh�r Globus";Globus Italia;"4 leitende, elastische B�nder f�r Oberschenkelanwendungen";45,90;G0479;"8032625826958";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/4-leitende-elastische-baender-fuer-oberschenkelanwendungen;2-3 Tage;"04791";https://www.cardiovibe.de/media/image/da/c1/86/elastische-leitende-baender_1280x1280.jpg;"In der Packung sind 4 elastische, leitende B�nder in 2 unterschiedlichen Gr��en enthalten. Man legt die B�nder um jeweils den oberen und unteren Teil des Oberschenkels. Dann wird das gew�nschte Programm an dem jeweils vorhandenem�Muskelstimulator ausgew�hlt. Die sinnvollsten Programme f�r di..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 12

"Magnetfeldtherapie>Zubeh�r Globus Magnetfeldger�te";Globus Italia;"Fester Solenoid 110x120mm";87,90;G0995;"8032625825739";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/fester-solenoid-110x120mm;2-3 Tage;"0995";https://www.cardiovibe.de/media/image/30/13/3c/starrer-solenoid-magnettherapie_1280x1280.jpg;"Fester Solenoid in den Ma�en 110x120mm mit gummierter Oberfl�che als Zubeh�r f�r Globus Magnum XL, Magnum XL Pro und Magnum 3000."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 13

"EMS Ger�te>Globus Italia";Globus Italia;"Globus Elite SII - Muskelstimulationsger�t";159,00;G3552;"8032625826040";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/muskelstimulationsgeraet-fuer-tens-ems/;2-3 Tage;"3552";https://www.cardiovibe.de/media/image/72/f1/ab/elite-s2-zweikanal-ems_1280x1280.jpg;"Hochwertiges, programmierbares 2-Kanal Muskelstimulationsger�t Der Globus Elite SII ist ein Muskelstimulationsger�t mit 100 Programmen - 30 Sport - 44 Fitness, Beauty & Wellness - 16 Schmerz & TENS - 6 Pr�vention - 3 Reha - 1 Inkontinenz Wenn Sie ein hochwertiges 2-Kanal EMS Ger�t suchen,..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 14

"Ballwurfmaschinen>Fu�ball";Globus Italia;"Globus EuroGoal 1000 Ballmaschine";5750,00;;"";;;0,00;120,00;0,00;0,00;https://www.cardiovibe.de/eurogoal-1000-ballmaschine-fussballtraining;2-3 Tage;"7326";https://www.cardiovibe.de/media/image/ed/aa/6a/eurogoal-1000-seite_1280x1280.jpg;"Die EuroGoal 1000 ist eine Ballschussmaschine, die entwickelt wurde, um ein modernes Fu�balltraining zu unterst�tzen. F�r viele Fu�ballvereine ist die EuroGoal Ballwurfmaschine mittlerweile zu einem unverzichtbaren Teil des Trainings geworden. Mit der Ballwurfmaschine ist es m�glich, in allen erd..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 15

"Magnetfeldtherapie>Magnetfeldtherapie Ger�te";Globus Italia;"Globus Magnum 3000 - Magnetfeld Ger�t";769,00;G3547;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/magnum-3000-magnettherapie;2-3 Tage;"3215";https://www.cardiovibe.de/media/image/bc/24/96/magnum-3000-magnettherapie_1280x1280.jpg;"Der Magnum 3000 ist das Magnetfeldger�t f�r professionelle Anwender wie Physiotherapeuten, Rehakliniken, aber auch interessierte Privatanwender. Das Ger�t verf�gt �ber eine gro�e Bandbreite unterschiedlicher Programme aus den Bereichen Anti Aging, Hautanwendungen, o..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 16

"Ballwurfmaschinen>Volleyball>Volleyball Ballmaschinen";Globus Italia;"Globus Winshot 800 Volleyball-Wurfmaschine";4180,00;;"";;;0,00;120,00;0,00;0,00;https://www.cardiovibe.de/winshot-800-volleyballmaschine;2-3 Tage;"7408";https://www.cardiovibe.de/media/image/14/0c/c0/winshot-800-ballmaschine_1280x1280.jpg;"Die Winshot 800 ist eine Ballschussmaschine speziell f�r professionelle Frauen-Volleyballteams und semi-professionelle Herrenteams. Mit der Winshot 800 sind Sie in der Lage, Hunderte von Aufgaben, wie Angriffe und Zuspielaktionen mit h�chster Pr�zision auszuf�hren. Die Maschine kann B�lle abschie..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 17

"Magnetfeldtherapie>Zubeh�r Globus Magnetfeldger�te";Globus Italia;"Flexibler Solenoid 450x150mm";146,90;G1408;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/flexibler-solenoid-450x150mm;2-3 Tage;"1408";https://www.cardiovibe.de/media/image/d1/a3/ce/flexbibler-solenoid-4-spulen_1280x1280.jpg;"Flexibler�Solenoid in den Ma�en 450x150mm mit 4�Spulen,�als Zubeh�r f�r Globus Magnum XL, Magnum XL Pro und Magnum 3000."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 18

"Magnetfeldtherapie>Zubeh�r Globus Magnetfeldger�te";Globus Italia;"Flexibler Solenoid 350x110mm";87,90;G1407;"8032625825746";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/flexibler-solenoid-350x110mm;2-3 Tage;"1407";https://www.cardiovibe.de/media/image/87/ab/a0/flexbibler-solenoid-magnetfeldzubehoer_1280x1280.jpg;"Flexibler�Solenoid in den Ma�en 350x110mm mit 2 Spulen,�als Zubeh�r f�r Globus Magnum XL, Magnum XL Pro und Magnum 3000."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 19

"EMS Ger�te>Globus Italia";Globus Italia;"Globus Swing - EMS Ger�t f�r Golfer";599,00;G3747;"8032625825944";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/globus-swing-ems-training-fuer-golfer/;2-3 Tage;"0864";https://www.cardiovibe.de/media/image/1b/f2/6e/swing-golf-muskelstimulator_1280x1280.jpg;"EMS Training zu Hause f�r Golfspieler Globus hat mit dem Swing ein weiteres EMS Ger�t aus der Sportler Linie entwickelt. Der Swing ist ein spezielles EMS Ger�t f�r Golfspieler . Dabei decken die zus�tzlich integrierten Spezialprogramme die wichtigsten Anforderungen ab, die beim Golf gefordert sin..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 20

"Hochfrequenzger�te>Radiofrequenzger�te";Globus Italia;"Globus RF Clinic Pro Radiofrequenzger�t";1399,00;G1506;"8032625825715";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/radiofrequenz-behandlung-rfclinic-pro;2-3 Tage;"1506";https://www.cardiovibe.de/media/image/7c/92/76/rf-clinic-pro_1280x1280.jpg;"Das Globus Hochfrequenz Ger�t RF Clinic Pro ist ein professionelles Hochfrequenzger�t, dass Radiofrequenzwellen f�r �sthetische Anwendungen nutzt. Diese Radiofrequenz (RF) Wellen werden f�r Anwendungen im Gesicht und am K�rper genutzt. Dank des neuen, innovativen RF-Kopfes, kann das Clinic Pro se..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 21

"Hochfrequenzger�te>Ultraschalltherapie";Globus Italia;"Globus Lipozero G 150";1490,00;G1398;"8032625825531";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/ultraschall-lipozero-g150;2-3 Tage;"1403";https://www.cardiovibe.de/media/image/7b/f6/7b/g-150-faltenbehandlung_1280x1280.jpg;"Das Lipozero G150 Ultraschallger�t von Globus Italia ist f�r professionelle Anwender, wie Physiotherapeuten oder Kosmetikstudios gedacht. Aber auch Privatanwender, die ein mit allen Features ausgestattetes, effektives Ultraschallger�t suchen, treffen mit dem Lipozero G150 eine gute Wahl. MF PLUS ..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 22

"Ballwurfmaschinen>Volleyball>Volleyball Ballmaschinen";Globus Italia;"Globus Winshot 1000";5355,00;;"";;;0,00;120,00;0,00;0,00;https://www.cardiovibe.de/globus-winshot-1000-volleyball-ballmaschine;2-3 Tage;"7410";https://www.cardiovibe.de/media/image/dc/d4/25/winshot-1000-volleyballmaschine_1280x1280.jpg;"Mit der Winshot 1000 hat Globus Italia eine Ballschussmaschine f�r den Volleyballsport entwickelt, die der technischen Evolution beim Volleyball gerecht wird: Angefangen bei der Volleyball-Jugend, f�r die ein schnelles und korrektes Techniktraining extrem wichtig ist, bis zu Profiteams, die auf e..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 23

"Magnetfeldtherapie>Zubeh�r Globus Magnetfeldger�te";Globus Italia;"B-Mat 200 Magnetfeldmatte";299,00;G3941;"8032625826675";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/magnetfeldmatte-globus-magnetfeldtherapie/;2-3 Tage;"3941";https://www.cardiovibe.de/media/image/c2/42/87/b-mat-magnetfeldmatratze_1280x1280.jpg;"Die Bed Mat (B-Mat) ist eine Magnetfeldmatte mit den Ma�en 176x70cm, die aus vier einzelnen Teilen besteht. Jedes Teil kann je nach Ausstattung vier Solenoide enthalten. Bei der B-Mat 200 Magnetfeldmatte sind das zwei aktive Abschnitte, die insgesamt 8 Solenoide (4 pro Abschnitt) enthalten. Die a..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 24

"EMS Ger�te>Zubeh�r Globus";Globus Italia;"Vaginal Elektrode - Blasenschw�che";26,00;G1188;"8032625826859";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/vaginal-elektrode-blasenschwaeche;2-3 Tage;"1188";https://www.cardiovibe.de/media/image/76/3a/b7/vaginal-elektrode-inkontinenz_1280x1280.jpg;"Mit der Vaginal�Elektrode von Globus Italia steht ein Zubeh�r f�r ausgew�hlte Globus EMS Ger�te zur Verf�gung, die �ber ein Inkontinenz Programm verf�gen. Mit diesem Stimulationsprogramm kann die Beckenbodenmuskulatur von Frauen per elektrischer Muskelstimulation trainiert werden. Unter Blas..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 25

"EMS Ger�te>Zubeh�r Globus";Globus Italia;"Anal Elektrode - Inkontinenz";36,00;G0757;"8032625827009";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/anal-elektrode-inkontinenz;2-3 Tage;"0757";https://www.cardiovibe.de/media/image/71/e3/a6/anal-elektrode-inkontinenz_1280x1280.jpg;"Mit der Anal Elektrode von Globus Italia steht ein Zubeh�r f�r ausgew�hlte Globus EMS Ger�te zur Verf�gung, die �ber ein Inkontinenz Programm verf�gen. Mit diesem Stimulationsprogramm kann die Beckenbodenmuskulatur per elektrischer Muskelstimulation trainiert werden. Unter Harn- und Stuhlinkontin..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 26

"Ballwurfmaschinen>Fu�ball";Globus Italia;"Globus EuroGoal 1500 Ballwurfmaschine";6725,00;;"";;;0,00;120,00;0,00;0,00;https://www.cardiovibe.de/eurogoal-1500-fussballmaschine;2-3 Tage;"7327";https://www.cardiovibe.de/media/image/a4/78/66/eurogoal-1500-ballmaschine_1280x1280.jpg;"Die innovative Ballwurfmaschine EuroGoal 1500 bringt das Fu�balltraining auf ein neues Level. Es k�nnen sowohl direkte Torsch�sse, Flanken, Eckb�lle, hohe B�lle, etc. gew�hlt werden, mit extremem Realismus und h�chster Effektivit�t. Die EuroGoal Ballschussmaschine eignet sich sowohl zum Torwarttr..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 27

"EMS Ger�te>Zubeh�r Globus";Globus Italia;"Myotrode Platinum Double Wire Elektroden 50x100mm (2St.)";2,90;G0458;"8032625826569";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/axelgaard-double-wire-elektroden;2-3 Tage;"0458";https://www.cardiovibe.de/media/image/f5/9b/3c/elektroden-axelgaard-doublewire_1280x1280.jpg;"Info: �Restposten mit empfohlenem Mindestverwendbarkeitsdatum 01/2015. Die Haftf�higkeit ist aber noch sehr gut, wir verkaufen die Elektroden aber drastisch reduziert. Die Myotrode Double Wire Platinum Elektroden werden vom renommierten Hersteller Axelgaard f�r Globus Italia hergestellt. Die..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 28

"Hochfrequenzger�te>Radiofrequenzger�te";Globus Italia;"Globus RF Beauty Mini Radiofrequenzger�t";299,00;G4259;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/radiofrequenzgeraet-fuer-zuhause;2-3 Tage;"4259";https://www.cardiovibe.de/media/image/48/83/56/rf-beauty-mini56cf0c53b83fa_1280x1280.jpg;"Das Globus RF Beauty Mini ist ein transportables Radiofrequenzger�t f�r zu Hause . Mit dem RF Beauty Mini k�nnen unterschiedliche �sthetische Anwendungen durchgef�hrt werden, wie unter anderem mit dem Programm Hautverj�ngung. Das handliche Ger�t, dass sehr gut f�r Heimanwendungen geeignet ist, ka..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 29

"Hochfrequenzger�te>Ultraschalltherapie";Globus Italia;"Globus Lipomed";199,00;G3470;"8032625825852";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/globus-lipomed-ultraschallgeraet;2-3 Tage;"3470";https://www.cardiovibe.de/media/image/ec/c6/14/lipomed-ultraschallgeraet_1280x1280.jpg;"Der neu auf den Markt gekommene Lipomed ist ein effektives, nicht-invasives und schmerzlos anzuwendendes Ultraschall-Ger�t. Mit diesem handlichen, kleinen Ultraschalltherapie-Ger�t k�nnen die wichtigsten Anwendungen ausgef�hrt werden. Dazu geh�ren Programme, die bei Cellulite, erh�htem K�rperfett..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 30

"EMS Ger�te>Globus Italia";Globus Italia;"Globus Premium 400 - EMS Ger�t Sport";399,00;G3551;"8032625825883";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/premium-400-sport-ems/;2-3 Tage;"0868";https://www.cardiovibe.de/media/image/bf/c9/25/premium-400-sport55b39c4874d42_1280x1280.jpg;"Im Premium 400 Muskelstimulator sind 2 innovative Technologien von Globus Italia integriert, die die Elektrostimulationsanwendungen im Beauty, Sport und dem medizinischen Bereich revolutioniert haben. Die 3S (serielle Sequenz Stimulation) und die ACTION NOW Technologie. Muskeltraining mit insgesa..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 31

"Hochfrequenzger�te>Diathermieger�te";Globus Italia;"Globus DiaCare 5000 - Diathermieger�t";7320,00;G3488;"8032625826002";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/diathermiegeraet-globus-diacare-5000;2-3 Tage;"3118";https://www.cardiovibe.de/media/image/2e/85/1e/diacare-5000-tecartherapie_1280x1280.jpg;"Neue Version des DiaCare 5000 - jetzt mit verschiedenen Frequenzen Der Globus DiaCare 5000 wurde vom Hersteller komplett �berarbeitet und bietet jetzt neben der 470 KHz Frequenz des Vorg�ngers, auch noch die Frequenzen 400, 700 und 1000 KHz. Dadurch kann der Anwender jetzt viel besser, je nach Ge..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 32

"EMS Ger�te>Globus Italia";Globus Italia;"Globus The Champion - Multisport EMS Ger�t";699,00;G5015;"8032625825920";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/multisport-muskelstimulator-leistungssport/;2-3 Tage;"5015";https://www.cardiovibe.de/media/image/9a/3b/7e/the-champion-ems_1280x1280.jpg;"Muskelstimulationsger�t f�r Spitzensportler, Trainer und Physiotherapeuten Das The Champion EMS Ger�t enth�lt alle innovativen Technologien von Globus Italia. Mit der 3S Sequenz Stimulation und der ACTION NOW Technologie stehen 2 Top Features zur Verf�gung, die speziell f�r sportspezifische Anwen..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 33

"Hochfrequenzger�te>Ultraschalltherapie";Globus Italia;"Globus Lipozero G 39 - Ultraschall Kavitation";1990,00;G1404;"8032625825340";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/ultraschall-kavitation-lipozero-g39;2-3 Tage;"1404";https://www.cardiovibe.de/media/image/f5/58/fa/g-39-kavitation_1280x1280.jpg;"Ultraschall Kavitations Ger�t mit 39KHz Frequenz.� Globus Italia hat den Lipozero G39 als Highend Ultraschall- und Kavitationsger�t vor allem f�r professionelle Anwender wie Kosmetikstudios, Physiotherapeuten, aber auch interessierte Privatanwender entwickelt. Die Ultraschall Technik kann be..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 34

"EMS Ger�te>Globus Italia";Globus Italia;"Globus Slimfit - EMS Gewichtsreduktion";299,00;G3727;"8032625825876";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/ems-gewichtsreduktion-slimfit-geraet/;2-3 Tage;"1251";https://www.cardiovibe.de/media/image/99/12/4c/slimfit-gewichtsreduktion55b3afe885cc6_1280x1280.jpg;"Der Slimfit von Globus | EMS Ger�t f�r Beauty-, Sport- und Anti-Aging Anwendungen. Insgesamt stehen in diesem professionellen EMS Ger�t 136 Programme zur Verf�gung, davon alleine 60 im Beauty Bereich. Hier die genaue Auflistung: 22 Sport | 32 Fitness | 60 Beauty | 12 TENS-Schmerz | 3 Reha | 1 Ink..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 35

"EMS Ger�te>Globus Italia";Globus Italia;"Globus Genesy 1500 - Physiotherapie";899,00;G3554;"8032625825906";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/genesy-1500-ems-tens-interferenz-geraet/;2-3 Tage;"1233";https://www.cardiovibe.de/media/image/fe/05/e3/genesy-15001_1280x1280.jpg;"F�r professionelle Anwendungen im medizinischen Bereich - der Genesy 1500, das neue Topmodell unter den EMS-Ger�ten. Nachdem der Genesy 1200 Pro �ber viele Jahre das Spitzenmodell f�r medizinische Anwendungen war, hat der Genesy 1500 die Nachfolge angetreten. Mit noch mehr Features, die wirklich ..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 36

"EMS Ger�te>Globus Italia";Globus Italia;"Globus Activa 700 - EMS Beauty";499,00;G3550;"8032625825890";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/ems-beauty-antiaging-activa-700/;2-3 Tage;"3550.1";https://www.cardiovibe.de/media/image/e0/4f/2a/activa-700_1280x1280.jpg;"Jede Menge fortschrittliche Technologien im Activa 700 EMS Beauty Ger�t Globus Italia pr�sentiert mit dem Activa 700 innovative Technologie, die den Markt der Muskelstimulationsger�te revolutioniert. Das gilt f�r die Bereiche Anti-Aging, Sport und den Bereich der medizinischen Anwendungen. Der Ac..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 37

"EMS Ger�te>Globus Italia";Globus Italia;"Globus Genesy 3000 - Elektrotherapie";999,00;G1034;"8032625825418";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/ems-physiotherapie-denerviert-genesy-3000/;2-3 Tage;"1367";https://www.cardiovibe.de/media/image/b7/6b/dd/genesy-3000-850x1000_1280x1280.jpg;"Der Genesy 3000 ist das Topmodell unter den medizinischen Elektrotherapie Ger�ten von Globus Italia. Das Ger�t ist gr��er als seine Vorg�nger und hat dabei ein ergonomischeres Design. Man kann den Genesy 3000 Pro als Elektrotherapie Ger�t sowohl mit dem Netzteil, als auch mobil mit dem integriert..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 38

"Hochfrequenzger�te>Ultraschalltherapie";Globus Italia;"Globus Medisound 3000 Ultraschallger�t";999,00;G1033;"8032625825210";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/globus-medisound-ultraschall-physiotherapie;2-3 Tage;"1033";https://www.cardiovibe.de/media/image/c8/6c/33/medisound-3000-physiotherapie_1280x1280.jpg;"Ultraschall Ger�t f�r die Physiotherapie. Das Ultraschallger�t Medisound 3000 in neuem Design, mit 49 vorinstallierten Programmen, davon 31 Beauty/Anti-Aging- und 18 Gesundheits-/Sportprogramme. Zus�tzlich k�nnen 30 Speicherpl�tze f�r eigene Programme genutzt werden. F�r professionelle Anwender b..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 39

"Magnetfeldtherapie>Magnetfeldtherapie Ger�te";Globus Italia;"Globus Magnum XL - Magnetfeldtherapie";399,00;G3216;"8032625825791";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/magnettherapie-geraet;2-3 Tage;"1409";https://www.cardiovibe.de/media/image/ce/4a/91/magnum-xl_1280x1280.jpg;"Das Magnettherapie-Ger�t Magnum XL von Globus Italia arbeitet mit Niedrigfrequenz - Magnetfeldern. Mit den neuen Magnetfeldanwendungen sind noch effektivere Behandlungen m�glich. Man kann mit den diversen Programmen sowohl gro�e Fl�chen wie den R�cken, als auch kleine K�rperregionen, wie die Gele..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 40

"EMS Ger�te>Zubeh�r Globus";Globus Italia;"Globus Fast Band Bauch-/R�ckengurt";59,00;G0487;"8032625825173";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/globus-fast-band-bauchtrainer;2-3 Tage;"0487";https://www.cardiovibe.de/media/image/79/4c/07/ems-bauchtraining_1280x1280.jpg;"EMS Bauch- / R�ckentraining Das Globus Fast Band ist perfekt f�r ein Training der Bauch- und R�ckenmuskulatur geeignet. Es kann mit allen 2- und 4-Kanal Muskelstimulatoren mit 2mm Steckern verwendet werden, also auch mit EMS Ger�ten anderer Hersteller. Globus hat das Fast Band speziell f�r Anwend..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 41

"EMS Ger�te>Zubeh�r Globus";Globus Italia;"Myotrode Platinum Elektroden 50x50mm (4St.)";9,90;G0136;"8032625826545";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/myotrode-axelgaard-50x50-elektroden;2-3 Tage;"0137";https://www.cardiovibe.de/media/image/7f/e0/27/ems-elektroden-quadratisch_1280x1280.jpg;"EMS / TENS Selbstklebeelektroden Hergestellt vom namhaften Hersteller Axelgaard f�r Globus Italia, sind die Myotrode Platinum Elektroden speziell f�r schwierige K�rperregionen mit unebener Struktur oder f�r empfindliche Hauttypen besonders gut geeignet. Ihre herausragende Leitf�higkeit und die gl..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 42

"Hochfrequenzger�te>Ultraschalltherapie";Globus Italia;"Globus Lipozero Excel";499,00;G1297;"8032625825449";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/ultraschallgeraet-lipozero-excel;2-3 Tage;"1402";https://www.cardiovibe.de/media/image/4b/ec/g0/lipozero-excel1-850x1000_1280x1280.jpg;"Der Lipozero Excel ist ein handliches Ultraschall-Ger�t f�r Anti-Aging und �sthetik in der Heimanwendungen. Das neue Design des Lipozero Excel und das intuitive Vollgrafik-Display macht die Nutzung sehr einfach. F�r Heimanwender bedeutet das, die Ultraschalltechnik bei Falten, Zellulitis, zur Dra..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 43

"EMS Ger�te>Zubeh�r Globus";Globus Italia;"Myotrode Platinum Elektroden 50x90mm (4 St.)";10,90;G0137;"8032625826552";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/axelgaard-platinum-elektroden;2-3 Tage;"0136";https://www.cardiovibe.de/media/image/e2/b4/bd/ems-selbstklebeelektrode_1280x1280.jpg;"EMS / TENS Elektroden von Axelgaard Mit extrem guter Haftung und Leitf�higkeit ausgestattet, werden die Myotrode Platinum Elektroden des namhaften Herstellers Axelgaard zur absoluten Nummer 1 bei der Elektrodenauswahl. Und das insbesondere dann, wenn es um die Stimulation an problematischen K�rpe..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 44

"EMS Ger�te>Zubeh�r Globus";Globus Italia;"Globus Elektroden Gel 260ml";3,50;G0484;"8032625821014";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/globus-elektroden-gel-260ml;2-3 Tage;"0484";https://www.cardiovibe.de/media/image/25/b3/d7/kontaktgel-elektroden_1280x1280.jpg;"Das Elektroden Gel von Globus Italia dient der Kontaktverbesserung zwischen Elektrode und der Haut beim Einsatz von Muskelstimulatoren, Ultraschall- und Hochfrequenz (RF) Ger�ten sowie�Pulsmessger�ten. Die Elektrostimulation wird dadurch angenehmer, das Kribbelgef�hl l�sst nach und die Leben..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 45

"EMS Ger�te>Zubeh�r Globus";Globus Italia;"Globus Fast Body Kit";79,00;G0488;"8032625825180";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/globus-fast-body-kit;2-3 Tage;"0488";https://www.cardiovibe.de/media/image/6e/13/a5/bauchtrainings-gurt_1280x1280.jpg;"Kombination aus Fast Band und Fast Pad Perfektes Zubeh�r f�r alle kompatiblen Muskelstimulatoren mit 2mm Stecker, f�r Bauch-/R�ckentraining (Fast Band) und Oberschenkeltraining (Fast Pad) Das Globus Fast Band kann an alle 2- und 4-Kanal Muskelstimulatoren von Globus Italia angeschlossen werden. D..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 46

"Hochfrequenzger�te>Ultraschalltherapie";Globus Italia;"Globus LipoZero";129,00;;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/globus-lipozero;2-3 Tage;"1484";https://www.cardiovibe.de/media/image/52/8a/64/lipozero_1280x1280.jpg;"Der LipoZero von Globus Italia ist ein handliches, kleines Ultraschallger�t f�r Heimanwendungen. Es ist ein effektives Instrument f�r �sthetikanwendungen des K�rpers und bietet nicht invasive, schmerzfreie Anwendungsm�glichkeiten. Der LipoZero nutzt Ultraschall Frequenzen, um die Beautyanwendunge..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 47

"Hochfrequenzger�te>Diathermieger�te";Globus Italia;"Globus DiaCare 3500 - Diathermie";6490,00;G3488;"8032625826002";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/diathermie-geraet-diacare-3500;2-3 Tage;"3834";https://www.cardiovibe.de/media/image/1e/7a/cc/diacare-3500-tecar-therapy55b7ff332ec57_1280x1280.jpg;"Das DiaCare 3500 Pro ist ein professionelles TECAR Therapie Ger�t aus der Diathermie Serie von Globus Italia, mit kapazitivem und resisitivem Energietransfer. Diese Ger�teserie ist f�r professionelle Anwender wie Physiotherapeuten, Reha Kliniken, etc. gedacht. Der Mechanismus�bei den Diather..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 48

"Magnetfeldtherapie>Magnetfeldtherapie Ger�te";Globus Italia;"Globus Magnum XL Pro Magnetfeldger�t";599,00;G3956;"8032625826200";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/magnetfeldtherapie-magnum-xl-pro;2-3 Tage;"3214";https://www.cardiovibe.de/media/image/49/00/1e/magnum-xl-pro1_1280x1280.jpg;"Handliches Magnetfeldtherapie Ger�t mit hoher Leistung. Wer ein Magnetfeldger�t mit professionellen Features und einer gro�en Bandbreite unterschiedlicher Programme sucht, f�r den ist das Magnum XL Pro das passende Produkt. Wie alle Ger�te von Globus Italia ist auch das Magnum XL Pro hochwertig v..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 49

"EMS Ger�te>Globus Italia";Globus Italia;"Globus Triathlon - EMS Ger�t f�r Triathleten";399,00;G3666;"8032625825937";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/ems-geraet-fuer-triathleten/;2-3 Tage;"3666";https://www.cardiovibe.de/media/image/d0/64/59/triathlon-ems-training_1280x1280.jpg;"F�r Triathleten, die das EMS Training in ihre Trainingsplanung integrieren wollen, hat Globus Italia mit dem Triathlon das perfekte EMS Ger�t entwickelt. Es wurde f�r die speziellen Anforderungen von Triathleten entwickelt. Alleine f�r die drei Sportarten Schwimmen, Radfahren und Laufen stehen 60..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 50

"EMS Ger�te>Zubeh�r Globus";Globus Italia;"Satz mit 4 farbigen Kabeln f�r Globus EMS Ger�te";35,00;G1839;"";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/satz-mit-4-farbigen-kabeln-fuer-globus-ems-geraete;2-3 Tage;"1839";https://www.cardiovibe.de/media/image/9b/e1/74/ersatzkabel-farbig-globus-ems_1280x1280.jpg;"Original Kabelsatz mit 4 farbigen Kabeln f�r alle Globus Italia 4-Kanal Muskelstimulatoren, f�r die Verbindung mit den Elektroden."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 51

"EMS Ger�te>Globus Italia";Globus Italia;"Globus Sail Pro - f�r Segler";599,00;G4232;"8032625826804";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/ems-training-segler-sail-pro/;2-3 Tage;"4232";https://www.cardiovibe.de/media/image/8d/92/57/sail-pro-ems-segler_1280x1280.jpg;"Mit dem Sail Pro hat Globus Italia ein EMS Ger�t speziell f�r Wassersportler auf den Markt gebracht. Der Sail Pro ist ein Elektrostimulationsger�t, dass neben den Standard EMS Programmen auch noch �ber spezielle Programme verf�gt, die f�r Wassersportler wie Segler, Windsurfer oder Kiter interessa..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 52

"EMS Ger�te>Zubeh�r Globus";Globus Italia;"Globus Motor Point Pen";29,00;G1156;"";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/globus-motor-point-pen;2-3 Tage;"G1156";https://www.cardiovibe.de/media/image/65/73/06/globus-motor-point-pen-ems_1280x1280.jpg;"Der Motor Point Pen dient zur korrekten Positionierung der Elektroden f�r eine effektive EMS Sitzung.� Der Globus Motor Point Pen kann vor einer EMS Sitzung genutzt werden, um den motorischen Reizpunkt des Muskels zu finden. So ist eine optimale Stimulation der jeweils trainierten Muskulatur..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 53

"Ballwurfmaschinen>Handball";Globus Italia;"Globus HandGoal 1500 - Handball Ballmaschine";5355,00;;"";;;0,00;120,00;0,00;0,00;https://www.cardiovibe.de/globus-handgoal-1500-handball-ballmaschine;2-3 Tage;"7441";https://www.cardiovibe.de/media/image/4c/f8/37/handgoal1500-ballmaschine56617516cbb40_1280x1280.jpg;"Die HandGoal 1500 ist das Topmodell unter den Globus Ballwurfmaschinen. Entwickelt speziell f�r professionelle Handballteams (M�nner und Frauen), die ihr Techniktraining weiter optimieren m�chten. Mit der HandGoal 1500 Ballwurfmaschine ist es m�glich, eine Angriffssituation aus unterschiedlichen ..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 54

"Hochfrequenzger�te>Ultraschalltherapie";Globus Italia;"Globus Medisound 922 Ultraschallger�t";249,00;G1502;"8032625825685";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/ultraschallgeraet-fuer-zuhause;2-3 Tage;"1502";https://www.cardiovibe.de/media/image/38/46/47/ultraschall-handgeraet_1280x1280.jpg;"Handliches Ultraschallger�t f�r zu Hause. Das neue Globus Medisound 922 ist ein multifunktionales Ultraschallger�t, dass bei Schmerzen unterschiedlichster Art angewendet werden kann. Hinzu kommen noch Programme f�r die Haut und allgemein den Beauty Bereich. Insgesamt stehen 3 verschiedene Anwendu..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 55

"Ballwurfmaschinen>Volleyball>Volleyball Ballmaschinen";Globus Italia;"Globus Winshot 500 Volleyball Ballmaschine";3695,00;;"";;;0,00;120,00;0,00;0,00;https://www.cardiovibe.de/globus-winshot-500-volleyball-ballwurfmaschine;2-3 Tage;"7407";https://www.cardiovibe.de/media/image/c3/06/d6/volleyball-maschine-beachvolleyball_1280x1280.jpg;"Die Winshot 500 von Globus Italia ist das Einstiegsmodell unter den Volleyball Ballwurfmaschinen. Gedacht ist die Winshot 500 speziell f�r semiprofessionelle Jugendteams (M�nner und Frauen) und f�r Beach Volleyballer. Mit ihr k�nnen hunderte von Aufgaben, Angriffsschl�gen oder Zuspielen mit h�chs..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 56

"EMS Ger�te>Globus Italia";Globus Italia;"Globus Genesy 600 - REHA, Physio, TENS";599,00;G1378;"8032625825913";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/genesy-600-ems-geraet-reha-denerviert/;2-3 Tage;"1378";https://www.cardiovibe.de/media/image/1c/bf/ac/genesy-600-reha-ems_1280x1280.jpg;"Professionelles EMS/TENS Ger�t f�r Physiotherapeuten Der Genesy 600 ist das ideale EMS Ger�t f�r Therapeuten und anspruchsvolle Privatanwender, die f�r die unterschiedlichsten Anwendungsbereiche ein hochwertiges EMS Ger�t suchen. Preislich liegt das Ger�t unter dem Genesy 1500 und 3000, bietet ab..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 57

"Ballwurfmaschinen>Fu�ball";Globus Italia;"Globus EuroGoal 600 Ballwurfmaschine";4379,00;;"";;;0,00;120,00;0,00;0,00;https://www.cardiovibe.de/guenstige-fussball-ballmaschine-fuer-fussballvereine;2-3 Tage;"7325";https://www.cardiovibe.de/media/image/69/f4/a4/eurogoal-600-amateure_1280x1280.jpg;"Es gibt mittlerweile viele bekannte Fu�ballvereine wie Arsenal, Atletico Madrid, Boca Juniors, die italienische Fu�ball Nationalmannschaft, etc., die ihr Training mit einer EuroGoal erweitern. Dabei k�nnen sowohl Torh�ter als auch Feldspieler gleicherma�en gut trainiert werden. Mit der Ballmaschi..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 58

"EMS Ger�te>I-TECH";I-TECH;"T-ONE PHYSIO";549,00;;"8019781471888";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/t-one-physio-ems-elektrotherapie;"4-5" Tage;"9150";https://www.cardiovibe.de/media/image/ac/04/0f/ems-t-one-physio_1280x1280.jpg;"Info: Die T-ONE Modelle sind nicht mehr lieferbar, sie wurden durch eine neue Ger�tegeneration ersetzt, die ab 01.09.2016 bestellbar sind. Der T-One Physio ist von der I-Tech Entwicklungsabteilung konzipiert worden, um die Anforderungen professioneller Anwender wie Physiotherapeuten, Rehakliniken..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 59

"EMS Ger�te>I-TECH";I-TECH;"T-ONE MEDI";299,00;;"8019781471086";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/t-one-medi-muskelstimulator;"4-5" Tage;"9170";https://www.cardiovibe.de/media/image/b2/8c/4f/t-one-medi-ems_1280x1280.jpg;"Info: Das T-ONE Medi ist nicht mehr lieferbar, es wurde mit dem T-One Medi Sport durch eine neue Ger�te Generation ersetzt. Mit dem T-One Medi hat I-TECH ein semi-professionelles Elektrostimulationsger�t im Programm, mit insgesamt 110 Programmen. Das T-ONE MEDI erm�glicht aufgrund von generierten..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 60

"EMS Ger�te>I-TECH";I-TECH;"I-TECH MIO - PERISTIM INKONTINENZ";229,00;;"8019781471666";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/mio-peristim-inkontinenz-therapie;2-3 Tage;"9190";https://www.cardiovibe.de/media/image/58/e6/3e/mio-peristim-ems-inkontinenz_1280x1280.jpg;"Der MIO-PERISTIM wurde speziell entwickelt, um bei Inkontinenz eingesetzt werden zu k�nnen (bei Stuhl- und Harninkontinenz). Insgesamt 9 unterschiedliche Inkontinenz Programme sind enthalten. Der MIO-PERISTIM wird zusammen mit der entsprechenden Sonde ausgeliefert. Bitte w�hlen Sie die gew�nschte..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 61

"EMS Ger�te>I-TECH";I-TECH;"T-ONE EVO II";229,00;;"8019781471697";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/t-one-evo2-ems-geraet;"4-5" Tage;"9175";https://www.cardiovibe.de/media/image/73/07/d6/t-one-evo2-ems_1280x1280.jpg;"Der T-ONE EVO II ist ein preisg�nstiger 4-Kanal Muskelstimulator, der vielf�ltig einsetzbar ist. Beim T-ONE EVO II liegt der Schwerpunkt bei Sport, Beauty und TENS Programmen. Nicht mehr verf�gbar! Der T-One Evo II ist durch den T-One Coach EMS ersetzt worden! Das Ger�t kann sehr gut f�r ein Trai..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 62

"EMS Ger�te>I-TECH";I-TECH;"I-TECH MIO-CARE FITNESS";149,00;;"8019781471123";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/mio-care-fitness-muskelstimulator;2-3 Tage;"9180";https://www.cardiovibe.de/media/image/3e/02/de/miocare-fitness-ems-training_1280x1280.jpg;"Mit dem Mio-Care Fitness hat I-Tech einen interessanten, preisg�nstigen 2-Kanal Muskelstimulator im Programm, mit 55 Programmen f�r �ber 500 Anwendungen. Das EMS Ger�t ist f�r jeden interessant, der das EMS Training in sein Fitnessprogramm integrieren m�chte. Daher liegt der Schwerpunkt bei den F..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 63

"Ballwurfmaschinen>Volleyball>Volleyball Zubeh�r";Globus Italia;"Batterie Pack Winshot";390,00;;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/batterie-pack-winshot;2-3 Tage;"7400BA";https://www.cardiovibe.de/media/image/ca/43/db/batterie-pack-winshot_1280x1280.jpg;"Batterie Pack bestehend aus zwei�12V-55AH Batterien und einem dazu passenden Ladeger�t. Das Batterie Pack kann mit allen Winshot Ballmaschinen genutzt werden, um unabh�ngig von einer externen Stromversorgung zu sein. Speziell f�r die Winshot 500 bietet sich das Batterie Pack an, da diese Bal..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 64

"EMS Ger�te>Zubeh�r Globus";Globus Italia;"Globus Fast Pad";38,90;G0489;"8032625825166";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/globus-fast-pad;2-3 Tage;"0489";https://www.cardiovibe.de/media/image/ee/f4/e5/fast-band-bauchtrainer-550x550_1280x1280.jpg;"Zubeh�r f�r alle kompatiblen Muskelstimulatoren mit 2mm Stecker, f�r ein effektives Oberschenkeltraining Das Globus Fast Pad kann an alle 2- und 4-Kanal Muskelstimulatoren von Globus Italia angeschlossen werden. Es ist aber auch kompatibel mit allen anderen Muskelstimulatoren mit 2mm Stecker (nic..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 65

"Hochfrequenzger�te>Diathermieger�te";Globus Italia;"Globus DiaCare 5000 RE - Diathermie Ger�t";1785,00;G3996;"8032625826842";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/diacare-diathermie-geraet;2-3 Tage;"3996";https://www.cardiovibe.de/media/image/2e/85/1e/diacare-5000-tecartherapie_1280x1280.jpg;"Professionelles Diathermie Ger�t zum kleinen Preis. Mit dem neuen DiaCare 5000RE wird die Diathermie auch f�r kleinere Physiotherapie Praxen bezahlbar. Der DiaCare 5000RE entspricht technisch dem normalen DiaCare 5000, mit dem Unterschied, dass eine andere Software verwendet wird. Mit dieser Soft..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 66

"EMS Ger�te>Zubeh�r Globus";Globus Italia;"TENS Elektroden 50x50mm (4St.) - selbstklebend";4,90;G0466;"";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/tens-elektroden-selbstklebend;2-3 Tage;"0466";https://www.cardiovibe.de/media/image/2b/a6/bf/tens-elektroden-kaufen_1280x1280.jpg;"G�nstige TENS Elektroden mit 2mm Stecker f�r passende TENS/EMS Ger�te. Die Myotrode TENS Elektroden von Globus Italia sind preisg�nstige Selbstklebeelektroden f�r kostenbewusste Nutzer von TENS Ger�ten. Die Leitf�higkeit ist nicht ganz so hoch, wie die der Platinum Elektroden und die Haftf�higkei..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 67

"EMS Ger�te>Zubeh�r Globus";Globus Italia;"TENS Elektroden 50x90mm (4St.) - selbstklebend";5,90;G0467;"";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/selbstklebende-elektroden-50x90;2-3 Tage;"0467";https://www.cardiovibe.de/media/image/20/8b/66/selbstklebeelektroden-tens_1280x1280.jpg;"Selbstklebende TENS/EMS Elektroden mit 2mm Stecker f�r Ger�te von Globus und anderen Herstellern. F�r kostenbewusste Nutzer von TENS/EMS Ger�ten sind die selbstklebenden Elektroden in der Gr��e 50x90mm die richtige Wahl. Es handelt sich um Standardelektroden mit den von vielen Herstellern verwend..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 68

"EMS Ger�te>I-TECH";I-TECH;"PHYSIO EMG - EMS + Elektromyographie";1490,00;;"8019781511010";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/physio-emg-elektromyographie-geraet;2-3 Tage;"9155";https://www.cardiovibe.de/media/image/7a/1e/bb/ems-elektromyographie_1280x1280.jpg;"Professionelles, innovatives Elektrotherapie Ger�t mit zus�tzlichen Elektomyographie Features. Das I-TECH Physio EMG verf�gt �ber 4 Kan�le und 2 unabh�ngige EMG Ausg�nge. Mit dem Physio EMG k�nnen simultan 2 Patienten mit jeweils unterschiedlichen Programmen behandelt werden. Das EMS / EMG Ger�t ..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 69

"Hochfrequenzger�te>Ultraschalltherapie";I-TECH;"I-TECH UE - Ultraschall + EMS";1390,00;I-TECH UE;"8019781460035";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/ultraschall-elektrotherapie-geraet;2-3 Tage;"9210";https://www.cardiovibe.de/media/image/81/d6/10/itech-ultraschall-tens_1280x1280.jpg;"Kombitherapie Ger�t mit EMS und Ultraschall. Aktionsangebot ! Nutzen Sie unseren Aktionspreis und erhalten noch 4 50x50mm + 4 50x90mm Platinum Elektroden gratis. Das I-TECH UE ist ein professionelles Ultraschall- und Elektrotherapieger�t. Physiotherapeuten k�nnen das Ger�t sowohl in der klassisch..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 70

"Magnetfeldtherapie>Magnetfeldtherapie Ger�te";I-TECH;"I-Tech Orthomag� - niederfrequentes Magnetfeldtherapieger�t";399,00;ORTHOMAG;"8019781011015";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/orthomag-pulsierendes-magnetfeldtherapiegeraet;2-3 Tage;"14010";https://www.cardiovibe.de/media/image/d3/6e/2e/orthomag-niederfrequenz-magnetfeldgeraet_1280x1280.jpg;"Das Orthomag� ist ein niederfrequentes Magnetfeldtherapieger�t, dass f�r die pulsierende Magnetfeldtherapie eingesetzt werden kann. Beim Orthomag handelt es sich um das erste Magnetfeldger�t, dass �ber einen flexiblen, superleichten und d�nnen, universell einsetzbaren Applikator verf�gt. Das gara..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 71

"Lasertherapie>Lasertherapieger�te";I-TECH;"I-TECH Trolley M";489,00;TROLL-M;"8019781802026";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/trolley-rollwagen-ultraschall/;2-3 Tage;"15060";https://www.cardiovibe.de/media/image/cf/10/0c/trolley-m_1280x1280.jpg;"Praktischer Ultraschall/Laser/Radiofrequenz/EMS Trolley mit 4 Doppel Lenkrollen, zwei mit Rollstop. An der S�ule des Trolleys befinden sich 2 integrierte Steckdosen. Zus�tzlich gibt es eine Befestigungsm�glichkeit f�r den schwenkbaren Arm, der als Zubeh�r f�r die Aufnahme der Ultraschall/Laser K�..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 72

"Lasertherapie>Lasertherapieger�te";I-TECH;"I-TECH LA 500 Lasertherapie";999,00;I-TECH LA-500;"8019781350015";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/lasertherapiegeraet-la-500;2-3 Tage;"15050";https://www.cardiovibe.de/media/image/7d/a4/cb/itech-laser-500mw_1280x1280.jpg;"Das Lasertherapieger�t LA 500 ist mit einer neuartigen Lasersonde ausgestattet, die es erlaubt, den Laser direkt auf den zu behandelnden Bereich zu lenken. Mit dem I-TECH LA 500 k�nnen Therapeuten die Ausgangsleistung (bis zu 500mW) und die Therapiezeit (bis zu 30 Minuten) nach den individuellen ..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 73

"Lasertherapie>Lasertherapieger�te";I-TECH;"I-TECH Schwenkbarer Arm f�r Trolley";389,00;ADJ-ARM;"8019781802040";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/verstellbarer-schwenkarm-ultraschall-laser/;2-3 Tage;"15065";https://www.cardiovibe.de/media/image/35/73/54/verstellbarer-arm_1280x1280.jpg;"Verstellbarer Schwenkarm f�r eine komfortable Behandlung des Patienten. Als Zubeh�r f�r den Trolley zur Aufnahme eines Ultraschall Kopfes oder der Laserdiode vom I-TECH LA 500 Lasertherapieger�t."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 74

"Hochfrequenzger�te>Ultraschalltherapie";I-TECH;"I-TECH UT2 - Ultraschalltherapieger�t";1150,00;TECH UT2;"8019781460028";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/ultraschalltherapiegeraet-fuer-professionlle-anwender/;2-3 Tage;"9215";https://www.cardiovibe.de/media/image/43/02/55/professionelles-ultraschall-therapie-geraet_1280x1280.jpg;"Professionelles Ultraschalltherapieger�t mit 2 Ultraschall K�pfen. Das I-TECH UT2 ist ein zertifiziertes Medizinprodukt. F�r Physiotherapie Einrichtungen, Reha Kliniken, aber auch anspruchsvolle Privatanwender, die ein professionelles Ultraschalltherapieger�t suchen, ist das I-Tech UT2 das passen..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 75

"Lasertherapie>Lasertherapieger�te";I-TECH;"I-TECH LA 8000 Lasertherapieger�t";5690,00;I-TECH LA-8000;"8019781561039";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/lasertherapie-geraet-la-8000;2-3 Tage;"15051";https://www.cardiovibe.de/media/image/f9/31/d9/itech-laser-8000_1280x1280.jpg;"Mit dem I-TECH LA 8000 k�nnen professionelle Anwender die Lasertherapie bei entz�ndlichen und degenerativen Erkrankungen im orthop�dischen, neurologischen und dermatologischen Bereich einsetzen. Das I-TECH LA 8000 Lasertherapieger�t erm�glicht eine Einstellung der Leistung (bis zu 8000mW) , der T..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 76

"Lasertherapie>Lasertherapieger�te";I-TECH;"I-TECH LA 10000 Lasertherapieger�t";7298,00;I-TECH LA-8000;"8019781561022";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/10-watt-lasertherapiegeraet;2-3 Tage;"15052";https://www.cardiovibe.de/media/image/62/d0/77/itech-laser-10000_1280x1280.jpg;"Der LA 10000 ist das Topmodell unter den I-TECH Lasertherapieger�ten. Mit einer Spitzenleistung von 10 Watt ist er auch f�r anspruchsvollste, professionelle Anwender perfekt geeignet. Wie schon das Modell LA 8000 ist er f�r die erg�nzende Behandlung vieler Beschwerdebilder im orthop�dischem, neur..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 77

"Lasertherapie>Lasertherapieger�te";I-TECH;"I-TECH Halterung f�r Laserkopf";59,90;LA-HEAD;"8019781802064";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/halterung-laserkopf/;2-3 Tage;"15066";https://www.cardiovibe.de/media/image/00/2e/g0/aufnahme-laser-kopf_1280x1280.jpg;"Halterung f�r die Befestigung am Schwenkarn, wie auf der zweiten Abbildung zu sehen ist. Mit der Halterung kann der Laserkopf bequem am Schwenkarm montiert werden. Das erm�glicht eine komfortable Stimulationssitzung f�r den Patienten. Geeignet f�r die Lasersonden des LA8000 + LA10000. �"

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 78

"Lasertherapie>Lasertherapieger�te";Globus Italia;"Globus Physiolaser 1000 Lasertherapieger�t";1690,00;G3579;"8032625826071";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/globus-physiolaser-1000-lasertherapie/;2-3 Tage;"3579";https://www.cardiovibe.de/media/image/92/26/ae/lasertherapiegeraet-physiolaser-1000_1280x1280.jpg;"Handliches Lasertherapieger�t f�r Physiotherapeuten. Der Globus Physiolaser 1000 kann zur Regeneration von entz�ndeten Gewebestrukturen, zur Zellregeneration und f�r eine Unterst�tzung der Mikrozirkulation eingesetzt werden. Besonders effektiv ist eine Lasertherapie mit dem Physiolaser 1000 in al..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 79

"Hochfrequenzger�te>Diathermieger�te";I-TECH;"I-TECH.AR Diathermieger�t";6490,00;I-TECH.AR;"8019781520012";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/diathermie-geraet-itech-ar/;2-3 Tage;"9220";https://www.cardiovibe.de/media/image/03/9e/fc/diathermiegeraet-tecar-therapie_1280x1280.jpg;"Die Diathermie, auch bekannt als TECAR Therapie (das Akronym steht f�r kapazitiven und resistiven Energietransfer), ist eine Technik, die den physiologischen Heilungsprozess stimulieren kann, durch eine Verk�rzung der Erholungszeit der motorischen Funktionen. Mithilfe der Diathermie kann die endo..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 80

"EMS Ger�te>I-TECH";I-TECH;"T-ONE COACH EMS";229,00;;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/t-one-coach-ems-fuer-sportler/;2-3 Tage;"9176";https://www.cardiovibe.de/media/image/64/7e/02/t-one-coach_1280x1280.jpg;"Der T-One Coach ist ein brandneues 4-Kanal EMS Ger�t, dass f�r die Muskelst�rkung und Pr�vention von Verletzungen bei Amateursportlern eingesetzt werden kann. Mit insgesamt 48 Programmen deckt der T-One Coach alle Anforderungen ab, die Sportler, aber auch Nichtsportler, an ein EMS Ger�t haben. Ne..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 81

"EMS Ger�te>I-TECH";I-TECH;"T-ONE MEDI SPORT";329,00;;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/ems-geraet-medi-sport;2-3 Tage;"9177";https://www.cardiovibe.de/media/image/fb/b7/ae/t-one-medi-sport_1280x1280.jpg;"Der T-One Medi Sport ist ein weiteres 4-Kanal EMS Ger�t aus der neu aufgelegten T-One Serie von I-Tech. Entwickelt wurde der Medi Sport vor allem f�r Sportler aller Disziplinen, die ihre Sportart professionell betreiben. Aber auch ambitionierte Breitensportler, die ein extrem vielseitiges EMS Ger..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 82

"EMS Ger�te>I-TECH";I-TECH;"T-ONE EVO I";169,00;;"8019781471390";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/guenstiges-4-kanal-ems-geraet/;"2-3" Tage;"9174";https://www.cardiovibe.de/media/image/7e/99/be/guenstiges-4-kanal-ems-geraet_1280x1280.jpg;"Info:� Es gibt eine neue Gener�te Generation bei den T-One Modellen, die Modelle Evo1, Evo2, Medi und Physio sind nicht mehr lieferbar. Mit dem T-One Evo I decken Sportler die wichtigsten Anforderungen an ein EMS Ger�t ab. So sind unter anderem die Programme Aufw�rmen, Muskelerholung, Kapill..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 83

"EMS Ger�te>I-TECH";I-TECH;"T-ONE MEDI PRO";429,00;;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/ems-geraet-physiotherapie-denerviert/;2-3 Tage;"9178";https://www.cardiovibe.de/media/image/f7/6b/9a/t-one-medi-pro57cd891f3abb7_1280x1280.jpg;"Mit dem T-One Medi Pro hat I-Tech ein neues 4-Kanal-Elektrotherapie Ger�t entwickelt, dass f�r einen professionellen Einsatz durch Sportmediziner, Physiotherapeuten, aber auch entsprechend ausgebildete Trainer gedacht ist. Die unterschiedlichen Programme sind so ausgelegt, dass sie f�r den Einsat..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 84

"EMS Ger�te>I-TECH";I-TECH;"T-ONE REHAB";499,00;;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/t-one-rehab-rehabilitation-sportmedizin/;2-3 Tage;"9179";https://www.cardiovibe.de/media/image/1b/cd/d1/t-one-rehab_1280x1280.jpg;"Das T-One Rehab ist ein hochprofessionelles 4-Kanal EMS Ger�t f�r die Rehabilitation. Entwickelt f�r den Einsatz in Rehabilitationskliniken, Krankenh�usern mit Schwerpunkt Orthop�die, f�r Fach�rzte, Physiotherapeuten und entsprechend qualifiziertes Fachpersonal. Im T-One Rehab sind alle wichtigen..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 85

"Hochfrequenzger�te>Ultraschalltherapie";I-TECH;"I-TECH UT1 - Ultraschalltherapie";1049,00;TECH UT1;"8019781460011";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/ultraschalltherapie-geraet-itech/;2-3 Tage;"9214";https://www.cardiovibe.de/media/image/d7/cf/12/ultraschalltherapie-geraet_1280x1280.jpg;"Das I-TECH UT1 ist ein hochwertiges Ultraschallger�t, dass alle Anforderungen professioneller Anwender in Bezug auf Benutzerfreundlichkeit, Leistung und Vielfalt der therapeutischen M�glichkeiten abdeckt. Im I-TECH UT1 sind 10 Programme vorinstalliert, es gibt aber die M�glichkeit, die einzelnen ..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 86

"Hochfrequenzger�te>Diathermieger�te";Globus Italia;"Globus RF Beauty 6000 MED - Diathermie";9900,00;G4332;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/rf-beauty-6000-diathermie-geraet/;2-3 Tage;"4332";https://www.cardiovibe.de/media/image/4d/ed/64/diathermie-geraet-antiaging_1280x1280.jpg;"Das Globus RF Beauty 6000 MED ist ein professionelles Diathermie Ger�t, dass f�r den Einsatz in Sch�nheitskliniken, Beauty Studios, aber auch f�r den Rehabereich entwickelt wurde. Insgesamt stehen 32 unterschiedliche Diathermie Programme zur Verf�gung. Mit dem RF Beauty 6000 MED kann in einem Rad..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 87

"EMS Ger�te>Globus Italia";Globus Italia;"Globus Fit&Beauty - EMS Ger�t";799,00;G1391;"8032625825845";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/globus-fit-beauty-ems/;2-3 Tage;"1391";https://www.cardiovibe.de/media/image/ab/ff/3c/ems-beauty-anwendung_1280x1280.jpg;"Mit dem Fit&Beauty hat Globus Italia ein professionelles EMS Ger�t im Programm, dass auch die anspruchsvollsten Anwender zufriedenstellt. Das Ger�t ist sowohl f�r den professionellen Einsatz in Kosmetikstudios und Sch�nheitskliniken gedacht, als auch f�r Privatanwender, die die gro�e Auswahl ..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 88

"Magnetfeldtherapie>Magnetfeldtherapie Ger�te";I-TECH;"I-Tech Mag 2000 - niederfrequente Magnetfeldtherapie";319,00;MAG 2000;"8019781472038";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/niederfrequentes-magnettherapiegeraet/;2-3 Tage;"14011";https://www.cardiovibe.de/media/image/79/ea/27/magnetfeldtherapiegeraet-fuer-zuhause_1280x1280.jpg;"Das MAG 2000 ist ein neues Magnetfeldtherapieger�t aus der I-Tech Magnettherapie Reihe. Komplett entwickelt und hergestellt vom renommierten Hersteller IACER aus Italien. Als Basis diente der erfolgreiche Vorg�nger ""My Mag"". Das MAG 2000 ist die konsequente Weiterentwicklung mit h�herer Leistung ..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 89

"EMS Ger�te>Zubeh�r Globus";Globus Italia;"Globus elastische B�nder f�r Oberschenkel 2St. 8x40cm";7,00;G1225;"";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/elastische-baender-iontophorese/;"2-3" Tage;"1225";https://www.cardiovibe.de/media/image/e2/be/94/baender-fuer-elektroden_1280x1280.jpg;"Die Packung enth�lt 2 elastische B�nder in den Ma�en 8x40cm, die zur Befestigung von nicht selbstklebenden Elektroden genutzt werden k�nnen. Unter anderem k�nnen die elastischen B�nder zur Befestigung von Iontophorese Elektroden an den Oberschenkeln verwendet werden."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 90

"EMS Ger�te>Zubeh�r Globus";Globus Italia;"Globus Adapter f�r Druckknopf Elektroden 4St.";6,00;G0727;"";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/adapter-fuer-druckknopf-elektroden/;2-3 Tage;"0727";https://www.cardiovibe.de/media/image/5c/82/0f/adapter-fuer-druckknopfelektroden_1280x1280.jpg;"Jede Packung enth�lt 4 Adapter Stecker, die f�r die Verwendung von runden Gesichtselektroden mit Clip und den Iontophorese Leder Elektroden verwendet werden m�ssen. So k�nnen die 2mm Elektroden Stecker der Globus EMS Ger�te mit den Clip Elektroden verwendet werden. Die Adapter Stecker k�nnen auch..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 91

"EMS Ger�te>Zubeh�r Globus";Globus Italia;"Globus elastischer Verl�ngerungsgurt f�r Fast Band";8,00;G1601;"";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/verlaengerungs-gurt-bauchgurt/;2-3 Tage;"1601";https://www.cardiovibe.de/media/image/f7/8c/b4/elastisches-verlaengerungsband_1280x1280.jpg;"Elastischer Verl�ngerungsgurt zur Verwendung mit dem Globus Fast Band. Geeignet f�r alle Personen mit gr��erem Taillenumfang, f�r die das Fast Band nicht nutzbar ist. Mit �dem Verl�ngerungsgurt kann das Fast Band auch von �bergewichtigen genutzt werden."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 92

"Hochfrequenzger�te>Ultraschalltherapie";EME Physio;"EME Combimed 4000 - EMS, Ultraschall, Laser";5490,00;CO1326;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/combimed-4000-ultraschall-ems-laser-kombi/;2-3 Tage;"CO1326";https://www.cardiovibe.de/media/image/4d/c1/66/combimed-4000_1280x1280.jpg;"Mit dem Combimed 4000 gibt es eine hochprofessionelle Physiotherapie Plattform in die 3 der beliebtesten Technologien integiert sind. Das Ger�t eignet sich f�r Physiotherapeuten und Reha Kliniken, aber auch f�r die Physio Abteilung von professionellen Vereinsmannschaften. Wenn es um schnelle Reha..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 93

"EMS Ger�te>Zubeh�r Globus";Globus Italia;"Globus Schwammelektrode f�r Iontophorese";6,00;G0890;"8032625825197";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/schwamm-elektrode-iontophorese/;2-3 Tage;"0890";https://www.cardiovibe.de/media/image/4c/57/67/schwamm-elektrode-ionophorese_1280x1280.jpg;"Hochwertige Schwammelektrode f�r Iontophorese Anwendungen mit geeigneten EMS Ger�ten, die �ber Iontophorese Programme verf�gen. Jede Elektrode besteht aus einem austauschbarem Schwamm (kann einzeln nachbestellt werden) und einer Silikonplatte. Die Schwammelektroden sind in 2 Gr��en verf�gbar, 50x..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 94

"Hochfrequenzger�te>Diathermieger�te";EME Physio;"EME Polyter Evo - Multi Therapiesystem";2290,00;PE0315;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/polyter-evo-therapiesystem/;2-3 Tage;"PE0315";https://www.cardiovibe.de/media/image/ef/b0/af/polyter-modulsystem5846b97d103a7_1280x1280.jpg;"Polyter Evo - mit BORA - hansgrohe zur Tour de France. Modulare, transportable Physiotherapie Einheit. Seit der Tour de France 2017 ist EME Physio offizieller Supplier des deutschen Profi Radsport Teams BORA - hansgrohe. Das Team nutzt den Polyter EVO f�r den mobilen Einsatz w�hrend der Rennen un..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 95

"Kombitherapie>Kombitherapie Ger�te";EME Physio;"EME Polyter Evo Module";1079,00;MU0001;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/polyter-evo-module/;2-3 Tage;"MU0001";https://www.cardiovibe.de/media/image/63/e6/14/polyter-evo-modulsystem5846b9d950a58_1280x1280.jpg;"Therapie Module f�r Polyter EVO. Auf dieser Produktseite haben Sie die M�glichkeit, die unterschiedlichen Therapiemodule f�r das Polyter Evo Basissystem zu bestellen. Die Module selbst sind eigenst�ndig nicht nutzbar, sondern nur in Kombination mit dem Polyter Evo . Sie sollten schon �ber das Bas..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 96

"Hochfrequenzger�te>Diathermieger�te";EME Physio;"EME HR TEK - Diathermie Standger�t";13690,00;HT1344;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/hr-tek-diathermie-standgeraet/;2-3 Tage;"HT1344";https://www.cardiovibe.de/media/image/bf/7f/08/hr-tek-diathermie_1280x1280.jpg;"Mit dem HR TEK kann EME-Physio auch die anspruchsvollsten Kunden zufrieden stellen. F�r gro�e Rehakliniken und Physiotherapiepraxen, aber auch f�r die sportmedizinische Abteilung von Erstliga Sportvereinen, ist das HR TEK die erste Wahl. Es ist ein innovatives Therapieger�t, dass die Diathermie (..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 97

"Hochfrequenzger�te>Diathermieger�te";EME Physio;"EME HR TEK DESK - Diathermie";10250,00;HT1343;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/hr-tek-desk-tecar-therapie/;2-3 Tage;"HT1343";https://www.cardiovibe.de/media/image/2a/f9/13/hr-tek-desk-tecar_1280x1280.jpg;"Mit dem HR TEK DESK gibt es noch einen kleinen Bruder des HR TEK Standger�tes . Das innovative Diathermie Ger�t bietet sich f�r professionelle Anwender wie Rehakliniken und Physiotherapiepraxen an. Die HR TEK DESK Version hat den Vorteil, dass das Ger�t auch au�er Haus direkt beim Patienten einge..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 98

"Lasertherapie>Lasertherapieger�te";EME Physio;"EME BiPower Lux Hochleistungslaser";8420,00;HL1362/6;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/hochleistungs-lasertherapie-geraet/;2-3 Tage;"HL13626";https://www.cardiovibe.de/media/image/c2/ee/ab/bipower-lux-laser_1280x1280.jpg;"BiPower Lux - die Evolution des Lichts. Lasertherapie direkt auf der Haut, ohne Verluste. Mit dem neuen Hochleistungslaser Sortiment hat EME Physio ein professionelles Lasersystem f�r Sportmediziner, Orthop�den, Physiotherapeuten und Haut�rzte entwickelt. Als Leiter f�r die Hochleistungs Laser (6..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 99

"EMS Ger�te>EME Physio";EME Physio;"EME THERAPIC 2000 - Elektrotherapie";1690,00;TH1310;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/therapic-2000-elektrotherapie-geraet/;2-3 Tage;"TH1310";https://www.cardiovibe.de/media/image/d3/11/50/therapic-2000-elektrotherapie_1280x1280.jpg;"EME Therapic 2000 - Business Line. EME Physio hat die Business Linie f�r diejenigen konzipiert, die ein Qualit�tsprodukt mit essentiellen Funktionen suchen. Auf Qualit�t und Leistung muss beim Therapic 2000 Elektrotherapie Ger�t nicht verzichtet werden. Es ist das passende Modell f�r alle Berufse..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 100

"EMS Ger�te>EME Physio";EME Physio;"EME Elektra 2 - Elektrotherapie";3190,00;EK1302;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/elektra-2-elektrotherapiegeraet/;2-3 Tage;"EK1302";https://www.cardiovibe.de/media/image/1e/4d/14/elektrotherapie-elektra-2_1280x1280.jpg;"Elektrotherapie in neuen Dimensionen. Das EME Elektra 2 Elektrotherapie-Ger�t hebt sich nicht nur durch die riesige Auswahl unterschiedlicher Stromarten von anderen EMS Ger�ten ab. Es ist auch in Sachen Benutzerfreundlichkeit richtungsweisend. �ber den 8 Zoll gro�en Touchscreen hat der Benutzer Z..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 101

"Hochfrequenzger�te>Diathermieger�te";EME Physio;"EME HR TEK BASIC";7990,00;;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/eme-hr-tek-basic-diathermiegeraet/;2-3 Tage;"HT1342";https://www.cardiovibe.de/media/image/e4/13/01/HR-Tek-Basic_1280x1280.jpg;"Das HR TEK BASIC ist ein leichtes und mobiles Diathermie (TECAR Therapie) Ger�t f�r Reha Kliniken und Physiotherapie Praxen. Es eignet sich f�r kapazitive und resisitive Diathermie Anwendungen, sowohl in der Klinik/Praxis, als auch f�r Hausbesuche. Aktuell als Aktionsangebot verf�gbar ! Funktione..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 102

"Lasertherapie>Lasertherapieger�te";EME Physio;"EME VIKARE HOCHLEISTUNGSLASER";4998,00;HL1360;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/eme-vikare-hochleistungslaser/;2-3 Tage;"HL1360";https://www.cardiovibe.de/media/image/22/c7/3d/vikare-hochleistungs-laser_1280x1280.jpg;"EME Physio hat mit der Vikare Produktlinie zwei neue Hochleistungs Laser im Sortiment. Der Vikare Laser ist als 4W und 8W Version bestellbar. Bei beiden Ger�ten wird der Laserstrahl ohne Verluste mit Hilfe von Glasfaserleitern direkt auf die Haut �bertragen. Die Vikare Laser k�nnen bei entz�ndlic..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 103

"Hochfrequenzger�te>Ultraschalltherapie";EME Physio;"EME Combimed 200";2190,00;CO1324;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/combimed-200-ems-ultraschall/;2-3 Tage;"CO1324";https://www.cardiovibe.de/media/image/4b/4c/79/ems-ultraschall-geraet_1280x1280.jpg;"Combimed 200 - EMS + Ultraschall Kombi. Aktionsangebot !� Aktuell erh�ltlich zum Sonderpreis + zus�tzlich 2 Beutel Platinum Elektroden (4x 50x90mm + 4x 50x50mm) gratis.� Mit dem Combimed 200 steht Physiotherapeuten ein Kombiger�t zur Verf�gung, in das EMS und Ultraschallanwendungen inte..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 104

"Hochfrequenzger�te>Ultraschalltherapie";EME Physio;"EME Combimed 2200";3290,00;CO1325;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/eme-combimed-2200-kombigeraet/;2-3 Tage;"CO1325";https://www.cardiovibe.de/media/image/aa/70/28/combimed-elektro-ultraschall_1280x1280.jpg;"Kombiniertes Elektrotherapie und Ultraschall Ger�t. Elektrotherapie Infos: In der Physiotherapie werden elektrotherapeutische Anwendungen daf�r eingesetzt, um denervierte Muskeln zu stimulieren und dadurch die Hypotrophie zu reduzieren, die durch eine Inaktivit�t des Muskels entsteht. Au�erdem ka..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 105

"Hochfrequenzger�te>Ultraschalltherapie";EME Physio;"EME US 50 - Ultraschallger�t Multifrequenz";1490,00;US1320;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/mehrfrequenz-ultraschall-therapie-geraet/;2-3 Tage;"US1320";https://www.cardiovibe.de/media/image/08/5b/99/ultraschallgeraet-multifrequenz_1280x1280.jpg;"Multifrequenz Ultraschallger�t EME US50 Kompaktes Tischger�t f�r die Ultraschall-Therapie, komplett mit 1/3 MHz Multifrequenz Behandlungskopf, aktuell zum Aktionspreis bestellbar. Ultraschall Effekte Durch die Ultraschallbestrahlung des Gewebes kommt es in den Zellen und Zwischenzellen zu einer H..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 106

"EMS Ger�te>EME Physio";EME Physio;"EME Therapic 7200/9200/9400";1790,00;TH1311;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/eme-therapic-elektrotherapie-geraete/;2-3 Tage;"TH1311";https://www.cardiovibe.de/media/image/a2/9c/d0/therapic-7200-ems_1280x1280.jpg;"EME Therapic 7200/9200/9400 Die 3 Ger�te der EME Prestige Line unterscheiden sich vorwiegend durch die jeweils integrierten Wellenformen. Au�erdem gibt es noch kleine Unterschiede bei der Anzahl der fest integrierten Programme. Im Gegensatz zum Therapic 7200 und 9200, beides 2-Kanal Ger�te, sind ..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 107

"Lasertherapie>Lasertherapieger�te";EME Physio;"EME Lasermed Kontaktlaser";1990,00;LT1371;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/eme-lasermed-kontaktlaser/;2-3 Tage;"LT1371";https://www.cardiovibe.de/media/image/cc/92/78/lasermed-2100_1280x1280.jpg;"EME Lasermed 2100 / 2200. Die Kontakt-Lasertherapie Bei der Laser-Therapie wird in Kontakt-Therapien und Scanning-Therapien unterschieden. F�r jede dieser Behandlungsarten kommen sowohl monodiodische als auch polydiodische Laser zum Einsatz. Die Behandlungsk�pfe werden bei der Kontakt-Therapie mi..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 108

"Lasertherapie>Lasertherapieger�te";EME Physio;"EME Scanning Laser PR 999";10250,00;SL1365;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/eme-scanning-laser/;2-3 Tage;"SL1365";https://www.cardiovibe.de/media/image/95/7e/90/scanning-laser-eme_1280x1280.jpg;"Gro�fl�chen Lasertherapie mit dem Scanning Laser. Physiotherapeuten steht mit dem Scanning Laser eine Lasertherapie Form zur Verf�gung, mit der gr��ere Fl�chen behandelt werden k�nnen, als mit der herk�mmlichen Kontakt-Therapie. Ein weiterer Unterschied, bei der Behandlung mit dem Scanning Laser ..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 109

"Lasertherapie>Lasertherapieger�te";EME Physio;"EME CRYSTAL YAG High Power Laser";15790,00;HL1363;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/crystal-yag-laser/;2-3 Tage;"HL1363";https://www.cardiovibe.de/media/image/8d/ea/9c/crystal-yag-hochleistungslaser_1280x1280.jpg;"Crystal Yag HPLS (High Power Laser System). Die beim Crystal Yag Laser genutzte Wellenl�nge von 1064nm liegt im ""therapeutischen Fenster"", dass im Bereich zwischen 400 und 1600nm liegt. Mit einer Laserleistung von 12W beim Desktop Modell und bis zu 25W beim Crystal Yag, ist eine hohe Gewebepenetr..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 110

"Hochfrequenzger�te>Ultraschalltherapie";Globus Italia;"Akku Pack MD 3000";84,90;G1120;"";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/globus-battery-pack-md3000/;"4-5" Tage;"1120";https://www.cardiovibe.de/media/image/83/fc/39/akku-fuer-ultraschall_1280x1280.jpg;"Zubeh�r f�r Medisound und Lipozero Das Battery Pack MD3000 mit 4000mA und 12V ist kompatibel mit folgenden Globus Ultraschallger�ten. Ein zus�tzliches Ladeger�t ist nicht erforderlich, da ein kombiniertes Netzteil/Ladeger�t schon zum Original Lieferumfang der Ger�te dazu geh�rt: 1. Medisound 3000..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 111

"EMS Ger�te>Zubeh�r Globus";Globus Italia;"Akku Pack G3000";35,00;G1127;"";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/globus-battery-pack-g3000/;2-3 Tage;"1127";https://www.cardiovibe.de/media/image/83/fc/39/akku-fuer-ultraschall_1280x1280.jpg;"Zubeh�r f�r Genesy 3000 Das Battery Pack G3000 mit 2000mA und 12V ist kompatibel mit dem Globus Genesy 3000. Ein zus�tzliches Ladeger�t ist nicht erforderlich, da ein kombiniertes Netzteil/Ladeger�t schon zum Original Lieferumfang des Ger�tes dazu geh�rt:"

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 112

"Hochfrequenzger�te>Ultraschalltherapie";I-TECH;"I-Tech Ultraschallkopf 1cm/2";168,00;MAN-1CMQ;"8019781460059";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/ultraschall-kopf-1cm/;2-3 Tage;"9209k1";https://www.cardiovibe.de/media/image/89/26/78/ultraschallkopf-1cm_1280x1280.jpg;"Zubeh�r f�r I-Tech UT-1 und UE Kleiner 1cm/2 Mehrfrequenz (1MHz - 3MHz) Ultraschallkopf f�r das I-Tech UT-1 Ultraschallger�t und das UE Ultraschall/EMS Kombiger�t."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 113

"Kombitherapie>Vakuumtherapie";EME Physio;"EME Vacuumed Vakuumtherapie";1990,00;VU1392;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/vacuumed-vakuumtherapie-geraet/;2-3 Tage;"VU1392";https://www.cardiovibe.de/media/image/c1/d9/0f/eme-vakuumtherapie-geraet_1280x1280.jpg;"Mit dem Vaccumed Vakuumtherapie Ger�t hat EME Physio die perfekte Erg�nzung f�r die Elektrotherapie- und Kombitherapieger�te der Combimed Serie im Programm. Die Vakuum Therapie ist eine therapeutische Methode, bei der �ber spezielle Vakuum Elektroden ein Saugnapfeffekt erzielt wird. Das dadurch e..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 114

"EMS Ger�te>Zubeh�r Globus";Globus Italia;"TENS Elektroden 50x90mm DOUBLE WIRE (2St.) - selbstklebend";6,90;G0448;"";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/double-wire-elektroden-50x90;2-3 Tage;"0448";https://www.cardiovibe.de/media/image/20/8b/66/selbstklebeelektroden-tens_1280x1280.jpg;"Selbstklebende TENS/EMS Elektroden mit 2x 2mm Stecker f�r Ger�te von Globus und anderen Herstellern. Die selbstklebenden Elektroden sind f�r kostenbewusste Nutzer von TENS/EMS Ger�ten in der Gr��e 50x90mm mit 2 Kabeln pro Elektrode die richtige Wahl. Es handelt sich um Standardelektroden mit den ..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 115

"Ballwurfmaschinen>Volleyball>Volleyball Zubeh�r";Bushnell;"Bushnell Velocity Speed Gun";239,00;101911;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/speed-gun-radarpistole-fussball/;2-3 Tage;"74032";https://www.cardiovibe.de/media/image/ba/66/81/radarpistole-ballmaschine_1280x1280.jpg;"Die Bushnell Velocity Radarpistole nutzt die Digitaltechnologie, um hochpr�zise Geschwindigkeitsmessungen mit einer Genauigkeit von +/- 1.8km/h durchf�hren zu k�nnen. Gedacht ist die Velocity Radarpistole als einfach zu handhabendes Me�instrument f�r Sport Enthusiasten, Vereinstrainer aus dem Ama..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 116

"Hochfrequenzger�te>Ultraschalltherapie";I-TECH;"I-TECH Mio-Sonic - Ultraschall Handger�t";189,00;MIO-SONIC;"8019781472175";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/ultraschalltherapie-handgeraet/;2-3 Tage;"9216";https://www.cardiovibe.de/media/image/e9/53/2b/mio-sonic-ultraschallgeraet_1280x1280.jpg;"Ultraschall Therapie f�r zu Hause. Mit dem Mio-Sonic hat I-Tech ein innovatives High-Performance Ger�t entwickelt, dass perfekt f�r die Ultraschalltherapie in den eigenen 4 W�nden geeignet ist. Die einfache Handhabung und die kompakte Gr��e, machen das Ger�t zu einem der kleinsten Ultraschallger�..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 117

"EMS Ger�te>Zubeh�r Globus";Globus Italia;"TENS Elektroden 26mm rund (30St.) - selbstklebend";14,50;G0871;"";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/gesichtselektroden-rund-26mm/;2-3 Tage;"0871";https://www.cardiovibe.de/media/image/95/84/15/26mm-gesichtselektroden_1280x1280.jpg;"Selbstklebende, runde TENS/EMS Gesichts Elektroden mit 2mm Stecker G�nstige Gro�packung mit 30 26mm Gesichtselektroden f�r TENS/EMS Ger�te mit 2mm Stecker. Der Trigger Punkt kann mit diesen kleinen Elektroden genauer angesteuert werden, als mit gr��eren Elektroden. Die selbstklebenden Gesichtsele..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 118

"EMS Ger�te>Zubeh�r Globus";Globus Italia;"Iontophorese Wildleder Elektroden";8,00;G0452;"";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/iontophorese-wildleder-elektroden/;2-3 Tage;"0452";https://www.cardiovibe.de/media/image/78/62/d4/iontophorese-wildleder-elektrode_1280x1280.jpg;"4 wiederverwendbare Iontophorese Wildleder Elektroden Die Wildleder Elektroden von Globus Italia eignen sich perfekt f�r alle Iontophorese Anwendungen. Mit der Iontophorese ist es m�glich, mit Hilfe eines schwachen, elektrischen Gleichstroms, ionisierte Arzneimittel in die Haut einzubringen. F�r ..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 119

"EMS Ger�te>I-TECH";I-TECH;"I-TECH Mio-Vein - FES Ger�t";114,90;MIO-VEIN;"8019781472649";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/mio-vein-venentraining/;2-3 Tage;"9182";https://www.cardiovibe.de/media/image/d2/0a/fe/fes-venenbeschwerden_1280x1280.jpg;"Spezielles FES (Funktionelle Elektrostimulation) Ger�t bei Venenbeschwerden und schweren Beinen Mit dem Mio-Vein hat I-Tech ein Zweikanal Ger�t entwickelt, dass f�r die elektrische Stimulation der Wadenmuskulatur entwickelt wurde und dadurch eine Unterst�tzung f�r einen normalen, ven�sen Blutkrei..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 120

"Hochfrequenzger�te>Diathermieger�te";Globus Italia;"Globus Diacare 7000 TECAR";12200,00;G3998;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/globus-diacare-7000-tecar/;2-3 Tage;"3998";https://www.cardiovibe.de/media/image/72/03/b9/globus-diacare-7000_1280x1280.jpg;"Mit dem Diacare 7000 hat Globus Italia k�rzlich sein aktuelles Topmodell auf den Markt gebracht. Im Vergleich zu seinem Vorg�nger, dem Diacare 5000, ist das neue Modell komplett �berarbeitet worden. Auch die Leistung ist noch einmal deutlich h�her. Maximal stehen jetzt 320W statt 200W beim Vorg�n..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 121

"Magnetfeldtherapie>Zubeh�r Globus Magnetfeldger�te";Globus Italia;"Solenoid Soft 4";139,90;G4276;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/weiche-magnetfeldmatte-4-magnetspulen/;2-3 Tage;"4276";https://www.cardiovibe.de/media/image/b0/5b/2b/softmatte-4-spulen_1280x1280.jpg;"Weiche Magnetfeldmatte mit 2 Kan�len und 4 eingearbeiteten Magnetfeldspulen in der Gr��e 25x25cm. Perfekt geeignet f�r R�cken-, H�ft-, Fu�- und Handanwendungen."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 122

"Magnetfeldtherapie>Zubeh�r Globus Magnetfeldger�te";Globus Italia;"Weiches Magnetfeld Kissen 12x12cm";65,00;G4275;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/magnetfeldkissen-fuer-magnettherapie/;2-3 Tage;"4275";https://www.cardiovibe.de/media/image/87/d5/8c/weiches-magnetkissen_1280x1280.jpg;"Weiches Magnetfeldkissen mit einer Magnetspule in den Ma�en 12x12cm. �Optimal f�r eine Magnetfeldtherapie von Kn�cheln, Ellbogen, Knien und Schultern. � �"

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 123

"Magnetfeldtherapie>Zubeh�r Globus Magnetfeldger�te";Globus Italia;"Mat 100 Magnetfeldmatte";119,90;G3938;"";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/magnetfeldmatte-mit-4-solenoiden/;2-3 Tage;"3938";https://www.cardiovibe.de/media/image/3a/ef/e3/mat-100-magnetfeldmatte_1280x1280.jpg;"Mit der Mat 100 bietet Globus Italia eine Magnetfeldmatte mit den Ma�en 44x70cm an. Die Matte ist mit 4 Solenoiden best�ckt, ein direkter Anschlu� an eines der Magnum Magnetfeldtherapie Ger�te ist problemlos m�glich."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 124

"Magnetfeldtherapie>Magnetfeldtherapie Ger�te";I-TECH;"I-Tech Mag 2000 Plus Magnetfeldtherapieger�t";499,00;MAG 2000 P;"8019781472045";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/mag-2000-plus-magnetfeldtherapie/;2-3 Tage;"14012";https://www.cardiovibe.de/media/image/af/ae/1c/mag-2000plus-magnettherapie_1280x1280.jpg;"Niederfrequentes Magnetfeldtherapieger�t mit hoher Leistung Das MAG 2000 Plus ist das leistungsst�rkste Magnetfeldtherapieger�t von I-Tech Medical. Mit 400 Gau� (200 Gau� pro Kanal) ist es auch f�r anspruchsvollste Anwender ausreichend stark dimensioniert. Die I-Tech Medical Division ist auch gle..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 125

"Hochfrequenzger�te>Ultraschalltherapie";Globus Italia;"Globus Medisound II Pro Ultraschallger�t";599,00;G1379;"8032625824145";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/globus-medisound-pro-ultraschalltherapie/;2-3 Tage;"1379";https://www.cardiovibe.de/media/image/61/8e/7f/globus-medisound-pro2_1280x1280.jpg;"Handliches Ultraschalltherapie Ger�t. In der neuen Ultraschall Professional Line von Globus Italia, ist der Medisound II Pro das Einstiegsger�t in die professionelle Ultraschalltherapie. Das Ger�t ist durch seine robuste Verarbeitung, dass unter allen Bedingungen gut ablesbare Display und seine i..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 126

"EMS Ger�te>Globus Italia";Globus Italia;"Globus Genesy 300 - Schmerztherapie, REHA";399,00;G3222;"8032625825814";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/genesy-300-ems-reha/;2-3 Tage;"3222";https://www.cardiovibe.de/media/image/97/b4/f0/genesy-300-physioems_1280x1280.jpg;"EMS/TENS Ger�t mit Mikrostrom und Ionophorese Der Genesy 300 ist f�r Physiotherapeuten und anspruchsvolle Privatanwender konzipiert worden, die ein EMS Ger�t f�r Anwendungen in der Schmerztherapie und Rehabilitation suchen. Das handliche Ger�t eignet sich auch perfekt f�r den mobilen Einsatz beim..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 127

"Hochfrequenzger�te>Ultraschalltherapie";I-TECH;"I-TECH Sonicstim Ultraschall- EMS Kombi";229,00;SONICSTIM;"8019781472311";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/ultraschalltherapie-ems-kombi/;2-3 Tage;"9218";https://www.cardiovibe.de/media/image/bf/10/e9/sonicstim-ultraschall-ems_1280x1280.jpg;"Ultraschall- / EMS Kombiger�t f�r zu Hause. Handliches, innovatives Ultraschall- / EMS Kombiger�t f�r Heimanwendungen oder ambulante Anwendungen durch einen Physiotherapeuten. I-Tech hat mit dem SONICSTIM ein ergonomisches Ger�t sowohl f�r die Ultraschalltherapie, als auch f�r TENS Anwendungen en..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 128

"EMS Ger�te>Globus Italia";Globus Italia;"Globus Elite 150";299,00;G1416;"8032625825562";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/elite-150-sport-ems-geraet/;2-3 Tage;"1416";https://www.cardiovibe.de/media/image/df/0a/f3/globus-elite-150_1280x1280.jpg;"Der neue Elite 150 von Globus | EMS Ger�t f�r Sport-, Beauty- und Anti-Aging Anwendungen. Wer ein gut ausgestattetes, aber dennoch preisg�nstiges 4-Kanal Ger�t sucht, der findet mit dem Elite 150 das passende EMS Ger�t. Es stehen insgesamt 150 Programme zur Verf�gung, davon 36 im Beauty Bereich. ..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 129

"EMS Ger�te>Zubeh�r Globus";Globus Italia;"Globus Elektroden Gel 1000ml";4,90;G0484;"";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/ultraschall-gel-1l/;2-3 Tage;"4034";https://www.cardiovibe.de/media/image/e9/11/59/elektroden-gel_1280x1280.jpg;"Hypoallergenes Elektroden Gel von Globus Italia - zur Kontaktverbesserung zwischen Elektrode und der Haut beim Einsatz von Muskelstimulatoren, Ultraschall- und Hochfrequenz (RF) Ger�ten sowie�Pulsmessger�ten. Die Elektrostimulation wird dadurch angenehmer, es kommt zu keinem unangenehmen Kri..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 130

"Magnetfeldtherapie>Zubeh�r ITech Magnetfeldger�te";I-TECH;"I-Tech Magnetfeld Matte 40x40cm";99,00;TAP2000;"8019781472090";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/therapeutische-magnetfeldmatte/;2-3 Tage;"TAP2000";https://www.cardiovibe.de/media/image/66/ed/29/magnetfeldmatte-klein_1280x1280.jpg;"Kleine, therapeutische Matte 40x40 cm mit 2 Kabeln und je 3 Solenoiden (insgesamt 6 Solenoide) f�r die Modelle MAG2000 und MAG2000 Plus."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 131

"Magnetfeldtherapie>Zubeh�r ITech Magnetfeldger�te";I-TECH;"I-Tech Elastischer Magnetfeldgurt mit Kabel";81,90;F3S2000;"8019781472052";;;0,00;3,90;0,00;3,90;https://www.cardiovibe.de/magnetfeldgurt-elastisch/;2-3 Tage;"F3S2000";https://www.cardiovibe.de/media/image/7c/ca/b4/magnetfeld-gurt-itech_1280x1280.jpg;"Therapeutischer, elastischer Gurt f�r niederfrequente, pulsierende Magnetfeldtherapie Ger�te. Mit Kabel und 3 Solenoiden pro Gurt. Kompatibel mit den Ger�ten MAG2000 und MAG2000 Plu."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Structural problem: Stray quote on row 132

"Magnetfeldtherapie>Zubeh�r ITech Magnetfeldger�te";I-TECH;"I-Tech Osteomat Magnetfeldmatte 4-teilig";239,00;OSTEOMAT;"8019781472236";;;0,00;0,00;0,00;0,00;https://www.cardiovibe.de/osteomat-magnetfeldmatte/;2-3 Tage;"OSTEOMAT";https://www.cardiovibe.de/media/image/g0/66/2b/magnetfeldmatte-gross_1280x1280.jpg;"Niederfrequente Magnetfeldtherapie Matte mit 2 Kabeln und insgesamt 6 Solenoiden. Die Magnetfeldmatte besteht aus 4 Segmenten, die zu einer Matte verbunden werden k�nnen. So kann der Ober- und Unterk�rper in nur einer Therapiesitzung behandelt werden. Das auf dem Bild zu sehende Magnetfeldtherapi..."

One or more values in the row have been incorrectly quoted. E.g. a comma has not been escaped, or a quoted field has not been properly escaped
Check the values in the column and ensure that quoting has been correctly applied.

Dialect: Non standard dialect

Although your CSV validates, to make it as easy as possible for your data to be reused, we recommend using commas as delimiters, double quotes to enclose fields, and autodetecting line endings.

Context problem: Incorrect Encoding

Your CSV appears to be encoded in ASCII-8BIT. We recommend you use UTF-8.

Context problem: Incorrect Encoding

Your CSV appears to be encoded in ASCII-8BIT. We recommend you use UTF-8.

Next Steps

Publish and transform your data using DataGraft, either as enhanced CSV or Linked Data.